IFR4000 Nav/Comm Flight Line Test Set

Equips the maintenance technician with the most portable nav/comm ramp test set on the market today

IFR4000
IFR4000 Nav/Comm Flight Line Test Set
IFR4000 Nav/Comm Flight Line Test Set
IFR4000 Nav/Comm Flight Line Test Set

The IFR 4000 is a compact, lightweight and weatherproof unit designed for testing ILS, VOR, Marker Beacon and VHF/UHF communications avionics systems.

The IFR 4000, with its lightweight size (under 8 lbs.), long run time battery (8 hrs) and ergonomic design, will provide the user with the most portable navigational communications ramp test set on the market today. Cockpit and bench use testing can be easily interchanged. The menu driven functionality and guided test capability make this instrument extremely easy to use. Combine these benefits with the outstanding price and the user has an instrument that delivers total value.

* Option 1 Required

NSN: 6625-01-516-4656 (IFR 4000)
NSN: 6625-01-559-2384 (IFR 4000AR)
NSN: 6625-01-553-1956 (IFR 4000 with ELT option installed)

Available through your GSA Supplier

Click here to get Software Updates

  • Accurate measurement of 121.5/243 MHz emergency beacon transmitter frequency, output power, modulation (AM). Headphone audio output to monitor swept tone *
  • Accurate measurement of 406 MHz COSPAS/SARSAT emergency beacon transmitter frequency, output power. Decode and display of all location and user protocols *
  • Accurate measurement of HF transmitter, frequency, output power, modulation (AM and SSB USB/LSB) receiver sensitivity
  • Accurate measurement of VHF/UHF transmitter, frequency, output power, modulation (AM and FM and receiver sensitivity)
  • Generation of ARINC 596 Selective Calling Tones
  • Accurate measurement of VHF/UHF antenna and or feeder SWR (Standing Wave Ratio)
  • Simulation of Localizer and Glideslope (CAT I, II and III) signals with variable DDM settings
  • Swept Localizer DDM for coupled Auto Pilot testing (Simultaneous Localizer, Glideslope and Marker signals)
  • Simulation of Marker Beacon, Selectable Airways (Z), Outer and Middle Marker Tones
  • Guided Test capability cuts down total test time
  • Low cost ELT option
  • Frequency counter provides external frequency measurement
  • MORSE CODE provides 1-4 characters transmitted in the VOR and ILS localizer mode
  • Eight or more hours of operation before recharge
  • Automatic power shut-down
  • Ergonomic design

Standard Accessories

  • 9140 Antenna, 75 MHz 9137 Antenna, telescoping
  • 10238 Transit case 6081 Operation Manual (CD)
  • 6087 Getting Started Manual
  • 67366 AC/DC power supply
  • 62302 Power cord, 110 V
  • 64020 Power cord set, 220 V
  • 62398 TNC (male) to TNC (male) coaxial cable
  • 24140 TNC (female) shorting cap
  • 56080 Spare fuse
  • 24141 50 Ω load
  • 63958 Flip cover (IFR 4000AR only)

Optional Accessories

  • 63656 Desk top stand
  • 62400 RS-232 cable
  • 6083 Maintenance Manual (CD)

Technical Specs

Applications

  • Support for ramp or bench environment via over-the-air or direct connection
  • Measurement of VHF/UHF transmitter, frequency, output power, modulation (AM and FM and receiver sensitivity)
  • Measurement of HF transmitter, frequency, output power, modulation (AM and SSB USB/LSB) receiver sensitivity
  • Accurate measurement of HF/VHF/UHF antenna and or feeder SWR (Standing Wave Ratio)
  • Simulation of Localizer and Glideslope (CAT I, II and III Ground Station) Signals with variable DDM settings
  • Swept Localizer DDM for coupled Auto Pilot testing (Simultaneous Localizer, Glideslope and Marker signals)
  • Simulation of VOR Beacon with variable bearing
  • Simulation of Marker Beacon, Selectable Airways (Z), Outer and Middle Marker Tones
  • Signal generation of VOR, Localizer, Glideslope and Marker Beacon
  • Signal generation and monitoring of COMM AM/FM/SSB
  • LS provides simultaneous Localizer, Glideslope and Marker Beacon signals
  • SELCAL decoder testing
  • Monitoring of Emergency Locator Transmitter (ELT), Emergency Position Indicating Radio Beacons (EPIRB) and Personal Locator Beacons (PLB)

Services

Avionics Maintenance and Repair Care Plans

VIAVI offers warranty and Avionics Maintenance and Repair Care Plans that include hardware and labor costs for repair, and annual certified calibrations performed at the factory during the duration of the service contract.

Avionics Maintenance and Repair Care Plan


Repair and Calibration

Our products live in rugged environments for over 10 years with 1000s of test connect/disconnect cycles.  We will be there to support you to ensure components that require maintenance like connectors, batteries, and software updates to ensure you are ready to test accurately for years to come. We apply factory procedures that use fast, automated calibration and functional verification, maintenance using OEM parts and the application of all engineering change orders and software updates. Services are available through contract Care plans, FleetCare or per incident as requests. 

Top 4 Reasons to Choose VIAVI for Your Repair and Calibration Needs:

  • Minimize business disruption
  • Budget
  • Measurement Accuracy and Product Reliability
  • Measurement Compliance, TL9000 certification and OEM Standards

Explore More


Care Support Plan - IFR4000

Care Support Plan - IFR4000

ProductRecommended Plan (Part Number)BronzeCare
BronzeCare
SilverCare
SilverCare
MaxCare
MaxCare
Why calibrate?
IFR4000IFR4000-5

Why calibrate this product?
What are the common issues?

Why Calibrate the product? AVX

Why Calibrate the product?

VIAVI Solutions performs a product performance check certifying the test equipment is performing within published specifications and updates the instruments internal calibration.  The calibration ensures accuracy and proper function of the instrument including required retrofits/repairs and firmware/software updates.

VIAVI Solutions conforms to one or more of the standards listed below as applicable to their product, location, and customer requirements. In keeping with this policy, the metrology and calibration processes provide an unbroken line of traceability to nationally and / or internationally recognized standards.

  • ISO 9001 Quality Management Systems - Requirements
  • ANSI/NCSL Z540-1 Calibration Laboratories Measuring and Test Equipment.

In addition, aviation ground support equipment (ramp or back shop), is required by the various aviation authorities around the world (including the FAA) to be maintained in accordance with the manufacturer recommendations, including calibration traceable to national standards.

What are the common issues? AVX

How will my measurements be affected if the product is out of calibration?

Tests performed with out of calibration test sets can return to service devices which are not performing to regulated specifications.

What are the most common implications of these issues to the business?

  • Inaccurate results: Calibration cycles greater than recommended may not yield accurate measurements
  • Inaccurate measurements resulting from uncalibrated tools may violate industry standards and violate regulatory body requirements
  • Tests found to be performed by an out of calibration test set can result in containment actions and unplanned rework
  • Devices calibrated on uncalibrated test sets may function improperly, cause interference issues violating government regulatory requirements, and/or damage other equipment

How to Get Started