Bert Module Cannot select RFC 2544

Tuesday, December 31, 2019
Submitted by ryan.grace on July 8, 2021 - 8:44pm
Problem: 
The RFC 2544 icon, on the MTS/TBERD Bert results screen, is grayed out and cannot be selected.
Solution: 
There are several potential settings conflicts that can make the RFC icon not accessible. Check the following SETUP parameters: 1. Timed Test must be disabled. 2. Payload Analysis must be enable on the Filters tab. 3. Test Mode cannot be set to anything other than Traffic. For a quick reset go TOOLS and select Reset Test to Defaults.