Knowledge Base - Solution

6000A MSAM in an 8000

Martes, Diciembre 31, 2019
Enviado por ryan.grace el Julio 8, 2021 - 8:44pm
Problem: 
Can I use the MSAM from my 6000A in an 8000 mainframe?
Solution: 
If the serial numer begins with A2 or A3 then the MSAM can used in an 8000 mainframe properly configured for bert module support. If the serial number starts with A1 then that module is too old to be used in a 8000 mainframe. The 8000 UIM must have a touch screen and a hard disk installed. Older 8000 version 1 units need to have a serial number of 4001 or higher to support a Dual Carrier with MSAM (does not apply to the version 2 8000E). The DMC needs to be an C8200 or higher. C8100 DMC's are only for fiber optic modules. 

Product Family:

Asistencia en cada paso

Proporcionamos soporte técnico, servicios, una formación completa y los recursos que necesita. Todo ello forma parte de lo que hacemos con el fin de maximizar el valor de su inversión en VIAVI.

Valor y servicios que complementan su catálogo de instrumentos y soluciones de sistemas VIAVI para proporcionar un coste total de propiedad excelente

Ofrecemos un servicio de atención al cliente que proporciona solicitudes de autorización de devolución de material (RMA) para tareas de reparación y calibración

Soluciones educativas técnicas, formación sobre productos y una formación combinada para técnicos que utilizan productos nuevos o trabajan con herramientas existentes

El centro de asistencia técnica (TAC) le ayudará a utilizar y configurar los productos y se encargará de los problemas relativos al rendimiento del producto