Knowledge Base - Solution

Capture not showing up on MSAM bert module.

Mardi, Décembre 31, 2019
Soumis par ryan.grace le 8 Juillet 2021 - 1:47pm
Problem: 
I have the capture option installed on my MSAM bert module but I have no setup or action tabs for capture.
Solution: 
Two things to check. First there are two capture options. One is High Speed for 10G LAN testing and one is Low Speed available on 1G and below ethernet rates. First check to ensure you have the correct option for the test you are launching. Second there are two versions of MSAM hardware. MSAM serial numbers that begin A1 or A2 are version 1 MSAMs and capture can only be performed from port 1. MSAM serial numbers that begin with A3 are version 2 MSAMs and capture can be performed from either port 1 or port 2. 

Product Family:

Suivi à chaque étape

Nous assurons l’assistance, les services, des formations complètes ainsi que les ressources qu’il vous faut. Tout cela dans le but de maximiser la valeur de vos investissements VIAVI.

Des prestations de service à valeur ajoutée qui optimisent le retour sur investissement de votre solution système et de votre gamme d’instruments VIAVI"

Un service client qui émet les autorisations de retour de matériel (Return Material Authorization, RMA) pour les réparations et la calibration.

Des solutions de formation technique, une formation à l’utilisation des produits et un enseignement mixte pour les techniciens qui utilisent de nouveaux produits ou travaillent avec les outils existants

Le centre d’assistance technique de VIAVI peut vous aider à utiliser/configurer vos produits ou à résoudre des problèmes liés aux performances des produits