Problem: 
What is the difference between single direction fiber testing and bidirectional fiber testing on the Viavi 40G Certifier? Is only one fiber attached for single?
Solution: 
Two fibers are always attached for 40G Certifier autotest fiber testing. When single direction is selected, on the 40G Certifier, Fiber 1 is tested from Local to Remote and Fiber 2 is tested from Remote to Local. If bidirectional is selected then both fibers are tested from both directions and the unit will prompt you to switch the fibers during the test. DO NOT switch the fibers at the connection to the testset. Removing the transmit fiber connection, at the testset, invalidates your reference. Switch the fibers at the connection to the panel.

Product Family:

Suivi à chaque étape

Nous assurons l’assistance, les services, des formations complètes ainsi que les ressources qu’il vous faut. Tout cela dans le but de maximiser la valeur de vos investissements VIAVI.

Des prestations de service à valeur ajoutée qui optimisent le retour sur investissement de votre solution système et de votre gamme d’instruments VIAVI"

Un service client qui émet les autorisations de retour de matériel (Return Material Authorization, RMA) pour les réparations et la calibration.

Des solutions de formation technique, une formation à l’utilisation des produits et un enseignement mixte pour les techniciens qui utilisent de nouveaux produits ou travaillent avec les outils existants

Le centre d’assistance technique de VIAVI peut vous aider à utiliser/configurer vos produits ou à résoudre des problèmes liés aux performances des produits