40G Ceritfier Copper Test Failures

Mardi, Décembre 31, 2019
Soumis par ryan.grace le 8 Juillet 2021 - 4:41pm
Problem: 
My copper tests keep failing on my Certifier 40G. What can I do to troubleshoot?
Solution: 
First make sure the correct limit is selected for the type of copper cabling that you are testing. Second make sure a proper reference was performed and if necessary re-reference the units. Check all connections at panel and jack fields. Wire should only be untwisted just enough to perform the termination and no more. Use the fault locator graph, on the cable test results, to identify the distance to the worst result which is most likely a connection of some type and re-terminate. If permanent link testing, check the probe count under the SYSTEM SETTINGS>SETTINGS 2DEVICE INFO. Viavi recommends that permanent link adapter cords be replaced after 5000 tests.

Product Family:

Suivi à chaque étape

Nous assurons l’assistance, les services, des formations complètes ainsi que les ressources qu’il vous faut. Tout cela dans le but de maximiser la valeur de vos investissements VIAVI.

Des prestations de service à valeur ajoutée qui optimisent le retour sur investissement de votre solution système et de votre gamme d’instruments VIAVI"

Un service client qui émet les autorisations de retour de matériel (Return Material Authorization, RMA) pour les réparations et la calibration.

Des solutions de formation technique, une formation à l’utilisation des produits et un enseignement mixte pour les techniciens qui utilisent de nouveaux produits ou travaillent avec les outils existants

Le centre d’assistance technique de VIAVI peut vous aider à utiliser/configurer vos produits ou à résoudre des problèmes liés aux performances des produits