Knowledge Base - How To

How to remove the battery from the ONX CATV

日曜日, 12月 29, 2019
作成者:ryan.grace 作成日:2月 1, 2023 - 10:41午後
Overview: 
This How-To document covers how to remove the battery from the ONX CATV
Solution Steps: 
Make sure that the unit does not have any cover case on Locate the 6 flat-head screws marked with the battery icon. Loosen each screw with a standard slotted screwdriver until you feel them disengage from the Mainframe portion of the unit. Note that these 6 screws are designed to remain captive with the Module. You will not be able to completely remove the screws out from the Module.User-added imageWith the unit still sitting face-down, lift the Module up and away from the Mainframe as shown. Removing the Module will expose a backplane connector that extends from the Mainframe. There is risk of damaging this backplane connector if the unit is pulled apart without exercising the proper caution. If the Module begins to lift away but appears to be still connected by one or more screws, further loosen each screw again until the Module lifts cleanly away from the Mainframe. If the Module sticks to the Mainframe even though the screws are fully loosened, you may need to use a tool to help “release” the seal created by the water sealing features. Refer to the "Optional Step" section for this step.User-added imageOptional Step. Note it is critical that this step only be performed if needed and only where specifically instructed. There is risk of damaging the water seal of the unit if these instructions are not followed. Gently insert a screwdriver as shown and use it to very carefully pry the two halves of the unit apart. Only do this until the Module begins to release from the Mainframe. Once the Module begins to release, go back to Step 3 to fully remove the ModuleUser-added imageOnce the “module” has been removed, then remove the screw on top of the battery cover.User-added imageOnce the battery cover has been removed, remove battery from unit.User-added imageAlfredo Fierro EMEA TAC

Product Family:

あらゆるステップでのサポート

VIAVIは、サポート、サービス、総合的なトレーニング、お客様が必要とするリソースを提供しています。これはすべて、お客様のVIAVIへの投資価値を最大化するために当社が日頃より行っていることです。

最適な総所有コスト(TCO)を実現するためにお客様のVIAVIシステムソリューションおよび機器ポートフォリオを補完する付加価値サービス

カスタマーサービスは、商品返品承認(RMA)番号を発行して修理や校正サービスを行います

新製品や既存のツールで作業を行う技術者に向けた技術教育ソリューション、製品トレーニングおよびブレンド型学習

技術支援センターは、製品の活用や設定の支援、製品の性能上の問題に対処します