PSD90-1C AC/DC Fuel Capacitance Test Set

Technologically advanced test set, providing multiple functions for calibration and troubleshooting

PSD90-1C AC/DC Fuel Capacitance Test Set

The PSD90-1C Universal AC/DC Capacitance Test Set will test any AC or DC Capacitive Fuel, Water, LOX or Engine Oil Quantity System*. The PSD90-1C has features that allow the user to better troubleshoot and isolate fuel system problems. Rugged in design, the unit can be used anywhere testing and troubleshooting is required. Capable of being operated with external power, the PSD90-1C is ideal for shop or Depot Level repair of fuel system components.

NSN: 4920-01-510-5628 Designed for F-16 fleet
NSN: 4920-01-528-2230 Designed for universal non-F16 fleet

*Aircraft-specific interface cables are required and must be purchased separately. 

Available through your GSA supplier

  • Easy to operate/calibrate
  • Annual calibration Lightweight / portable
  • Rechargeable battery or externally powered
  • Percent of battery capacity displayed
  • Self-test on power-up
  • Measures DC voltage Manual or Auto Ranging
  • 2 and 3 Wire Meggar
  • Compliant with Boeing Spec 10-61959 Rev H
  • MIL-STD-810 Method 511.4 certified
  • Traceable to NIST
  • Tests any AC or DC capacitive fuel, water, LOX/engine oil or other AC capacitive system*

Versions

  • *877 PSD90-1C/60-110 AC/DC Capacitance Test Set (110 V) PN: 01-1000-60 NSN: 4920-01-510-5628 Designed for F16 fleet
  • 878 PSD90-1C/61-110 AC/DC Capacitance Test Set (110 V) PN: 01-1000-61 NSN: 4920-01-528-2230 Designed for universal non-F16 fleet

Aircraft specific interface cables are required and must be purchased separately.

Standard Accessories

  • 57934 CBL PSD90-1C charger 110 V
  • 57939 CBL PSD90-1C charger 230 V
  • 75538 Operations Manual PSD90-1C
  • 38647 Connector BNCF Rev. Polarity
  • 38648 Connector BNCM Rev. Polarity
  • 57929 GND Cable
  • 57947 Interface 472844 F16 Simulator (Order Number: 877 only)

Optional Accessories

  • 853 Precision Transfer Standard PTS-1 JPN: 01-0978-50 NSN: 6625-01-497-5942

Spécifications Techniques

Size

  • 10.6” x 14” x 6.5” (26.9 cm x 35.6 cm x 16.5 cm)
  • 13 lbs

Services

Avionics Maintenance and Repair Care Plans

VIAVI offers warranty and Avionics Maintenance and Repair Care Plans that include hardware and labor costs for repair, and annual certified calibrations performed at the factory during the duration of the service contract.

Avionics Maintenance and Repair Care Plan


Repair and Calibration

Our products live in rugged environments for over 10 years with 1000s of test connect/disconnect cycles.  We will be there to support you to ensure components that require maintenance like connectors, batteries, and software updates to ensure you are ready to test accurately for years to come. We apply factory procedures that use fast, automated calibration and functional verification, maintenance using OEM parts and the application of all engineering change orders and software updates. Services are available through contract Care plans, FleetCare or per incident as requests. 

Top 4 Reasons to Choose VIAVI for Your Repair and Calibration Needs:

  • Minimize business disruption
  • Budget
  • Measurement Accuracy and Product Reliability
  • Measurement Compliance, TL9000 certification and OEM Standards

Explore More


Care Support Plan - PSD90-1C

Care Support Plan - PSD90-1C

ProductRecommended Plan (Part Number)BronzeCare
BronzeCare
SilverCare
SilverCare
MaxCare
MaxCare
Why calibrate?
PSD90-1CPSD-XX-Silver-5

Why calibrate this product?
What are the common issues?

Why Calibrate the product? AVX

Pourquoi calibrer ce produit ?

VIAVI Solutions performs a product performance check certifying the test equipment is performing within published specifications and updates the instruments internal calibration.  The calibration ensures accuracy and proper function of the instrument including required retrofits/repairs and firmware/software updates.

VIAVI Solutions conforms to one or more of the standards listed below as applicable to their product, location, and customer requirements. In keeping with this policy, the metrology and calibration processes provide an unbroken line of traceability to nationally and / or internationally recognized standards.

  • ISO 9001 Quality Management Systems - Requirements
  • ANSI/NCSL Z540-1 Calibration Laboratories Measuring and Test Equipment.

In addition, aviation ground support equipment (ramp or back shop), is required by the various aviation authorities around the world (including the FAA) to be maintained in accordance with the manufacturer recommendations, including calibration traceable to national standards.

What are the common issues? AVX

Quel impact un mauvais calibrage du produit aura-t-il sur mes mesures?

Tests performed with out of calibration test sets can return to service devices which are not performing to regulated specifications.

Quels sont les problèmes les plus courants?

  • Inaccurate results: Calibration cycles greater than recommended may not yield accurate measurements
  • Inaccurate measurements resulting from uncalibrated tools may violate industry standards and violate regulatory body requirements
  • Tests found to be performed by an out of calibration test set can result in containment actions and unplanned rework
  • Devices calibrated on uncalibrated test sets may function improperly, cause interference issues violating government regulatory requirements, and/or damage other equipment

Comment commencer