IFR6015 Military Flight Line Test Set

Features an extremely easy to use interface where every parameter the user commonly needs to view is displayed on screen

Supports military IFF transponder modes and TACAN

IFF-7300S Series IFF/Crypto/TACAN Automated Test System
IFF-7300S Series IFF/Crypto/TACAN Automated Test System

The IFR6015 is a compact, lightweight and weatherproof unit designed for testing Transponder Modes 1,2,3A,C,S, TCAS I, II, and Military E-TCAS, TIS as well as DME/TACAN. IFF Modes 1,2 and TACAN are standard on all new units. For upgrades to existing units contact VIAVI Solutions. NSN: 6625-01-574-2423.

Radiated Testing:
The IFR6015 is supplied with a lightweight fully sealed directional antenna that may be test set mounted, hand held or tripod mounted.

Direct Connect Testing:
The IFR6015 may be directly connected to the UUT via a supplied RF coax cable via the RF I/O port.

Direct Connect with Coupler Testing:
Isolated testing can be accomplished with use of an optional single or dual coupler kit for diverse systems.

Standard Accessories

  • 10241 Transit case
  • 62302 Power cord, 110 V
  • 64020 Power cord set, 220 V
  • 62401 TNC/TNC COAX, 12 in.
  • 112830 TNC/TNC COAX, 72 in.
  • 56080 Fuse, 5 Amp, 32 V
  • 112684 Antenna
  • 64749 Antenna shield
  • 64580 Breakout box
  • 67366 Power supply
  • 6100 Getting Started Manual
  • 6097 Operation Manual - CD(AC0825CD)

VERSIONS, OPTIONS AND ACCESSORIES

  • 72424 IFR6015 Mode 1,2,3A/C/S Transponder, TACAN/DME, TCAS I,II,E-TCAS, TIS Ramp Test Set NSNs: 6625-01-578-4893 6625-01-574-2423 6625-01-601-4034* * Most current NSN, and is identified on unit serial tag
  • 83411 6000OPT3 ADS-B 1090 MHz
  • 112795 6000OPT5 UAT 978 MHz (for units with Mod 2 upgrade installed)
  • 141751 Kit, UAT upgrade (includes Opt. 5 and Mod 2 upgrade)
  • 140609 6000OPT6 ADS-B Integrity Test Option (cables included)

Especificaciones técnicas

Applications 

  • Verifify the performance of: 
    • MK10A, MK12 & MK12/S IFF Transponders (excluding Mode 4) 
    • Mode S, ATCRBS, ADS-B and UAT transponders
    • TACAN T/R & A/A Interrogators
    • DME A/A Interrogators
    • ADS-B and UAT receivers via target generation
    • TIS, TCAS I or II, and E-TCAS systems
  • Emulate preset modes of TACAN Test Sets: Generic DoD, AN/ASM-663, AN/ ARM-184, Bradley 2650 & 2655

Servicios

Avionics Maintenance and Repair Care Plans

VIAVI offers warranty and Avionics Maintenance and Repair Care Plans that include hardware and labor costs for repair, and annual certified calibrations performed at the factory during the duration of the service contract.

Avionics Maintenance and Repair Care Plan


Repair and Calibration

Our products live in rugged environments for over 10 years with 1000s of test connect/disconnect cycles.  We will be there to support you to ensure components that require maintenance like connectors, batteries, and software updates to ensure you are ready to test accurately for years to come. We apply factory procedures that use fast, automated calibration and functional verification, maintenance using OEM parts and the application of all engineering change orders and software updates. Services are available through contract Care plans, FleetCare or per incident as requests. 

Top 4 Reasons to Choose VIAVI for Your Repair and Calibration Needs:

  • Minimize business disruption
  • Budget
  • Measurement Accuracy and Product Reliability
  • Measurement Compliance, TL9000 certification and OEM Standards

Explore More


Care Support Plan - IFR6015

Care Support Plan - IFR6015

ProductRecommended Plan (Part Number)BronzeCare
BronzeCare
SilverCare
SilverCare
MaxCare
MaxCare
Why calibrate?
IFR6015IFR6015-5

Why calibrate this product?
What are the common issues?

Why Calibrate the product? AVX

¿Por qué calibrar este producto?

VIAVI Solutions performs a product performance check certifying the test equipment is performing within published specifications and updates the instruments internal calibration.  The calibration ensures accuracy and proper function of the instrument including required retrofits/repairs and firmware/software updates.

VIAVI Solutions conforms to one or more of the standards listed below as applicable to their product, location, and customer requirements. In keeping with this policy, the metrology and calibration processes provide an unbroken line of traceability to nationally and / or internationally recognized standards.

  • ISO 9001 Quality Management Systems - Requirements
  • ANSI/NCSL Z540-1 Calibration Laboratories Measuring and Test Equipment.

In addition, aviation ground support equipment (ramp or back shop), is required by the various aviation authorities around the world (including the FAA) to be maintained in accordance with the manufacturer recommendations, including calibration traceable to national standards.

What are the common issues? AVX

¿Cuáles son los problemas habituales?

Tests performed with out of calibration test sets can return to service devices which are not performing to regulated specifications.

¿Cómo se verán afectadas las mediciones si el producto no está correctamente calibrado?

  • Inaccurate results: Calibration cycles greater than recommended may not yield accurate measurements
  • Inaccurate measurements resulting from uncalibrated tools may violate industry standards and violate regulatory body requirements
  • Tests found to be performed by an out of calibration test set can result in containment actions and unplanned rework
  • Devices calibrated on uncalibrated test sets may function improperly, cause interference issues violating government regulatory requirements, and/or damage other equipment

Primeros pasos

¿Le interesa una demostración de algún producto? Póngase en contacto con nosotros para obtener más información, recibir un presupuesto o averiguar cómo adquirir un producto.