ATC-5000NG NextGen Transponder/DME Test Set and ADS-B Target Generator

NextGen ATC/DME Test Set

Prepare for Global ATC Modernization with NextGen test technology

ATC-5000NG NextGen Transponder
ATC-5000NG NextGen Transponder
ATC-5000NG NextGen Transponder

Software-driven design allows for field updates for adding new features, capability or modifications due to industry changes

The ATC-5000NG is an RF signal generator/receiver for testing Mode A, C and S transponders. The ATC-5000NG was designed with modern software defined radio technology and is the replacement product for the commercial functionality of the SDX-2000, ATC-1400A and S-1403DL. The test set was designed for engineering development, design validation, manufacturing and return-to-service testing.

Click here to get Software Updates

  • Software-driven design allows for field updates for adding new features, capability or modifications due to industry changes
  • ADS-B Target Generator
  • ADS-B squitter encode/decode
  • DO-260, DO-260A and DO-260B data parsing
  • DO-260B canned tests available (option)
  • Generates ATCRBS/Mode S interrogations Multi-receiver test capability (option)
  • UAT TX/RX capability (optional)
  • Pulse and frequency measurement
  • 10.4 inch touch screen LCD display for operator control of all test set capabilities
  • Remote controlled via GPIB or Ethernet
  • Two independent transmitters and receivers
  • TX/RX data logging capability
  • Full diversity testing capability
  • Data parsing in engineering units

Equipment Tested

  • Transponders Mode S/ADS-B Out
  • ADS-B In Receivers
  • UAT Transceivers
  • 1090MHz DF18 Emitters (surface vehicles)
  • ADS-B In Ground Station Receivers
  • ADS-R, TIS-B Ground Station Transmitters
  • DMEs

Technical Specs

Applications 

  • Engineering development, certification, manufacturing and service
  • Capable of performing most MOPS tests for DO-181E, DO-260, DO-260A, DO-260B, DO-282B

Size

  • 10.5”H x 19”W x 24”D (26.7 cm x 48.3 cm x 60.9 cm)
  • Weight: 41 lbs. (18.6 kg)

服务

Avionics Maintenance and Repair Care Plans

VIAVI offers warranty and Avionics Maintenance and Repair Care Plans that include hardware and labor costs for repair, and annual certified calibrations performed at the factory during the duration of the service contract.

Avionics Maintenance and Repair Care Plan


Repair and Calibration

Our products live in rugged environments for over 10 years with 1000s of test connect/disconnect cycles.  We will be there to support you to ensure components that require maintenance like connectors, batteries, and software updates to ensure you are ready to test accurately for years to come. We apply factory procedures that use fast, automated calibration and functional verification, maintenance using OEM parts and the application of all engineering change orders and software updates. Services are available through contract Care plans, FleetCare or per incident as requests. 

Top 4 Reasons to Choose VIAVI for Your Repair and Calibration Needs:

  • Minimize business disruption
  • Budget
  • Measurement Accuracy and Product Reliability
  • Measurement Compliance, TL9000 certification and OEM Standards

Explore More


Care Support Plan - ATC-5000NG ATC/DME Test Set

ProductRecommended Plan (Part Number)BronzeCare
BronzeCare
SilverCare
SilverCare
MaxCare
MaxCare
Why calibrate?
ATC-5000NGATC-5000NG-5

Why calibrate this product?
What are the common issues?

Why Calibrate the product? AVX

为什么要校准这个产品?

VIAVI Solutions performs a product performance check certifying the test equipment is performing within published specifications and updates the instruments internal calibration.  The calibration ensures accuracy and proper function of the instrument including required retrofits/repairs and firmware/software updates.

VIAVI Solutions conforms to one or more of the standards listed below as applicable to their product, location, and customer requirements. In keeping with this policy, the metrology and calibration processes provide an unbroken line of traceability to nationally and / or internationally recognized standards.

  • ISO 9001 Quality Management Systems - Requirements
  • ANSI/NCSL Z540-1 Calibration Laboratories Measuring and Test Equipment.

In addition, aviation ground support equipment (ramp or back shop), is required by the various aviation authorities around the world (including the FAA) to be maintained in accordance with the manufacturer recommendations, including calibration traceable to national standards.

What are the common issues? AVX

如果产品不在校准范围内,我的测量结果会受到怎样的影响?

Tests performed with out of calibration test sets can return to service devices which are not performing to regulated specifications.

有哪些常见问题?

  • Inaccurate results: Calibration cycles greater than recommended may not yield accurate measurements
  • Inaccurate measurements resulting from uncalibrated tools may violate industry standards and violate regulatory body requirements
  • Tests found to be performed by an out of calibration test set can result in containment actions and unplanned rework
  • Devices calibrated on uncalibrated test sets may function improperly, cause interference issues violating government regulatory requirements, and/or damage other equipment

如何开始