MAP-2800

Rack-mounted test head for centralized and standalone Ethernet/BER tests.

The one tool data center operators and service providers need to remotely test transmission quality, wavelength services, and carrier's carrier services.

Data centers protect against data loss by replicating data to other sites over high-performance network links. Keeping those links at full performance — and proving it against SLAs — requires regular Ethernet and Bit Error Rate (BER) testing across line rates up to 800G, plus OTN, WDM, Fiber Channel, and SONET/SDH circuits. Most data centers, though, run lean, with few if any technicians on-site to do that testing.  

The MAP-2800 solves this: it lets data center operators and network service providers run high-performance BER tests securely and remotely, even at unmanned sites — so link quality gets verified without a truck roll.  

Service providers need high-speed testing solutions to test 400G/800G services via their fiber optic backbone to other service providers or data center operators.  This solution integrates seamlessly with the existing portfolio of field test instruments including ONA-800, NSC-200, ONX, and T-BERD/MTS-5800.

MAP-2800 can also be used as a centralized test head under the Fusion Ethernet test system offering customers a comprehensive portfolio of test devices that cover everything from virtual test agents to Smart SFP's and centralized test heads up to 800G. 

Ethernet Testing From 10 Mbps to 800G
One platform covers the full speed range needed for data center interconnects, converged Ethernet/IP networks, and telco access-to-core links.

Part of the Fusion Ethernet Test Solution
Can be used as 400G/800G test head under the Fusion system along side virtual test agents, smart SFP's, and the whole set of VIAVI field test instruments.

Industry-Fastest Ethernet Service Activation
RFC 2544 and Y.1564 (SAMComplete™) with nanosecond-accurate latency, plus RFC 6349 (TrueSpeed™) for throughput validation.

Automated OTN and Optics Validation
The OTN Check workflow automates OTN service activation, while the field-optimized Optics Self-Test confirms SFP-DD, QSFP-DD, and OSFP modules run error-free.

Remote, Unmanned Rack Deployment
A compact 1.5U, 19" rack-mount design (21"/23" kits available) with remote management enables unattended transmission-quality testing of data center, central office, and submarine cable network links.  Field-replaceable dual power supply and fans