VIAVI TestCenter: Why VIAVI TestCenter reports an error "Interface IPv4 x on Device Host x has invalid Network Stack" on apply?
Knowledge Base - FAQ
VIAVI TestCenter: Why VIAVI TestCenter reports an error "Interface IPv4 x on Device Host x has invalid Network Stack" on apply?
• Based on the error, the device configured with IPv4 encapsulation.
Error Detail: Multicast MAC Address configured for Source MAC Address
ERROR messages from Logs:
1/16/2013 12:38:14 .7 Error Other Interface EthIIIf: Multicast MAC address is not allowed for emulated devices (Host x)
1/16/2013 12:38:14 .7 Info Other Interface IPv4 x on Device Host x has invalid Network Stack. Please see log for details
07:10:94:00:00:01 is a Multicast MAC Address
RESOLUTION:
• Since this is a Layer 3 Unicast device, set the Ethernet Source Mac Address to a Unicast MAC Address.
Example 06:10:94:00:00:01
IANA MAC Detail: