Certifier

The industry standard in enterprise certification for both copper and fiber network certification.

The VIAVI Certifier equips technicians with all the capabilities they need to certify both copper and fiber networks quickly, completely, and correctly for all current and future cabling standards for the new enterprise.

To test and certify copper up to Category 6A, the Certifier10G is the cost-effective solution. Without support for fiber or Class FA, the Certifier10G is an entry-level copper certifier with the same benefits as Certifier40G.​

Drive user efficiency
The Certifier is not only the most advanced solution available, it is also the fastest and most complete. Whether certifying copper or fiber, users will get the job done right and on time…the first time!

  • The industry’s fastest CAT6A solution can certify each cable within 9 seconds, saving users 30 minutes each time they test 150 CAT6A cables*
  • Tier 1 certification of multimode and single-mode fiber in less than 6 seconds
  • Automate pass/fail end-face analysis for all fiber types
  • Gain complete test visibility at both local and remote ends
  • Pre-configured with all leading manufacturer’s cabling specifications

Key Benefits

  • Achieve complete network certification with one device
  • Optimize productivity with the industry’s fastest test workflow
  • Obtain comprehensive results for the latest TIA-568 and ISO 11801 requirements
  • View test set up and results data and edit labels at both local and remote ends

Applications

  • Complete TIA 568/ISO 11801 copper and fiber certification
  • TIA-942-A data center certification
  • Objective pass/fail inspection to IEC 61300-3-35 fiber end-face requirements. Learn more

Features

  • Permanent link and channel adapters for certifying to TIA category 5e/6/6A and ISO class D/E/EA/F/FA
  • Multimode (850/1300 nm) and single-mode (1310/1550 nm) adapters for Tier 1 fiber certification (loss/length/polarity)
  • Industry-leading VIAVI P5000i digital fiber end-face inspection probe support
  • Integrated, standards-based certification labeling and reporting

Featured Resources

Application Notes

Brochures

Case Studies

Data Sheets

Manuals & User Guides

Quick References

Selection Guides

Services

Vendor Approvals

Repair and Calibration

Our products live in rugged environments for over 10 years with 1000s of test connect/disconnect cycles.  We will be there to support you to ensure components that require maintenance like connectors, batteries, and software updates to ensure you are ready to test accurately for years to come. We apply factory procedures that use fast, automated calibration and functional verification, maintenance using OEM parts and the application of all engineering change orders and software updates. Services are available through contract Care plans, FleetCare or per incident as requests. 

Top 4 Reasons to Choose VIAVI for Your Repair and Calibration Needs:

  • Minimize business disruption
  • Budget
  • Measurement Accuracy and Product Reliability
  • Measurement Compliance, TL9000 certification and OEM Standards

Explore More


Care Support Plan - Certifier

Care Support Plan - Certifier

ProductRecommended Plan (Part Number)BronzeCare
BronzeCare
SilverCare
SilverCare
MaxCare
MaxCare
Why calibrate?
Certifier 10/40G local & remoteMaxCare-5

Why calibrate this product?
What are the common issues?

Why calibrate this product?

Validate measurement accuracies conform to published specifications.

Factory standards to ensure accuracy

Factory standards to ensure accuracy

VIAVI Calibrates to TL9000 factory standards to ensure your instrument is certified to measure accurately, as it did when it came off the factory line.  Instruments that are out of calibration will produce unreliable measurements and can create false passing or false failing test results that often cause your team repeat work.  We maintain, polish and clean all fiber connectors, fix pigtail connections that are internal to the product to ensure all ports stay in good working order and upgrade software / firmware to the latest approved release to enable enhancements. VIAVI Care Plans are the most cost-effective way to plan for calibration with a low, discounted price at the time of instrument purchase, however fixed rate calibration can be purchased at a later date on a separate purchase order.

  • Ensure accurate measurements that meet calibration and service level agreements, ISO and TL standards for network test procedures.
  • Ensure all test transmission signals work properly to avoid issues such as not reaching full line rate testing rate required to validate service bandwidth, speed and quality of service (QoS).
  • Maintain ports and connectors to keep test transmissions working properly and to extend the life of the instrument. For example, if optical connectors and, lasers are bad or electrical/RF interface ports are loose after years of connection cycles, OTDR, TDR, and Radio Frequency measurements will not work properly.
  • When doing construction, installation and activation work that must be certified, all network components typically must be tested with a certified, calibrated instrument to preserve warranty from manufacturer, such as fiber optic cable manufactures. 
  • Accurate RF frequencies and optical wavelengths are critical to meet measurement specifications.  If using these to validate network elements, power levels, transmission rates, out of specification tools will prevent validation of network elements and signals.

How will my measurements be affected if the product is out of calibration?

Full mfg warranty (20-30 years) from cable suppliers (e.g. Corning, Commscope, Belden, ...) will only be granted if the installation is certified with a calibrated instrument.

What are the most common implications of these issues to the business?

What are the most common implications of these issues to the business?

  • Uncalibrated tools produce unreliable measurement results that can't be certified to specifications and may violate service level agreements or ISO/TL9000 standards with your customers and their network equipment vendors.
  • QoS certification may be inaccurate and generate a repeat test need. Contractors are often not compensated or could be delisted as an approved service supplier due to incorrect results.
  • Full manufacturer  warranty (20-30 years) from cable suppliers (e.g. Corning, CommScope, Belden, ect.) will only be granted if the installation is certified with a calibrated instrument, thus the network owner is motivated to comply with correct installation certification procedures to retain and enforce the warranty on expensive cabling and optical network elements, etc.

Common Business impacts include:

  • Lost revenue, customer complaints and increased costs: 
  • Most network operators track and audit repeat work done by sub-contractors and often there is a billing dispute in these cases.  Contractors with high rates of inaccurate test results are usually hired for less or not at all when not meeting SLA agreements or quality metrics.   
  • For Network Operators, repeat service quality issues with customers often causes added cost, customer dissatisfaction and loss of business.  

Example:

Let's look at OTN/SONET/SDH/E1/T1 and various FTTX, DOCIS and xDSL measurements.  It is critical to reach full line rate (1G, 10G, 40G, 100G) to test service performance and service error rates.  If the uncalibrated tester can not reach full line rate during testing, a customer may be left with suboptimal performance that will quickly create complaints or alternatively, the technician could end up chasing phantom network problems that do not exist.

Certifier 40G Fiber adaptersMaxCare-5

Why calibrate this product?
What are the common issues?

Why calibrate this product?

Validate measurement accuracies conform to published specifications.

Factory standards to ensure accuracy

Factory standards to ensure accuracy

VIAVI Calibrates to TL9000 factory standards to ensure your instrument is certified to measure accurately, as it did when it came off the factory line.  Instruments that are out of calibration will produce unreliable measurements and can create false passing or false failing test results that often cause your team repeat work.  We maintain, polish and clean all fiber connectors, fix pigtail connections that are internal to the product to ensure all ports stay in good working order and upgrade software / firmware to the latest approved release to enable enhancements. VIAVI Care Plans are the most cost-effective way to plan for calibration with a low, discounted price at the time of instrument purchase, however fixed rate calibration can be purchased at a later date on a separate purchase order.

  • Ensure accurate measurements that meet calibration and service level agreements, ISO and TL standards for network test procedures.
  • Ensure all test transmission signals work properly to avoid issues such as not reaching full line rate testing rate required to validate service bandwidth, speed and quality of service (QoS).
  • Maintain ports and connectors to keep test transmissions working properly and to extend the life of the instrument. For example, if optical connectors and, lasers are bad or electrical/RF interface ports are loose after years of connection cycles, OTDR, TDR, and Radio Frequency measurements will not work properly.
  • When doing construction, installation and activation work that must be certified, all network components typically must be tested with a certified, calibrated instrument to preserve warranty from manufacturer, such as fiber optic cable manufactures. 
  • Accurate RF frequencies and optical wavelengths are critical to meet measurement specifications.  If using these to validate network elements, power levels, transmission rates, out of specification tools will prevent validation of network elements and signals.

How will my measurements be affected if the product is out of calibration?

Full mfg warranty (20-30 years) from cable suppliers (e.g. Corning, Commscope, Belden, ...) will only be granted if the installation is certified with a calibrated instrument.

What are the most common implications of these issues to the business?

What are the most common implications of these issues to the business?

  • Uncalibrated tools produce unreliable measurement results that can't be certified to specifications and may violate service level agreements or ISO/TL9000 standards with your customers and their network equipment vendors.
  • QoS certification may be inaccurate and generate a repeat test need. Contractors are often not compensated or could be delisted as an approved service supplier due to incorrect results.
  • Full manufacturer  warranty (20-30 years) from cable suppliers (e.g. Corning, CommScope, Belden, ect.) will only be granted if the installation is certified with a calibrated instrument, thus the network owner is motivated to comply with correct installation certification procedures to retain and enforce the warranty on expensive cabling and optical network elements, etc.

Common Business impacts include:

  • Lost revenue, customer complaints and increased costs: 
  • Most network operators track and audit repeat work done by sub-contractors and often there is a billing dispute in these cases.  Contractors with high rates of inaccurate test results are usually hired for less or not at all when not meeting SLA agreements or quality metrics.   
  • For Network Operators, repeat service quality issues with customers often causes added cost, customer dissatisfaction and loss of business.  

Example:

Let's look at OTN/SONET/SDH/E1/T1 and various FTTX, DOCIS and xDSL measurements.  It is critical to reach full line rate (1G, 10G, 40G, 100G) to test service performance and service error rates.  If the uncalibrated tester can not reach full line rate during testing, a customer may be left with suboptimal performance that will quickly create complaints or alternatively, the technician could end up chasing phantom network problems that do not exist.

Certifier 40G MPO adaptersMaxCare-5

Why calibrate this product?
What are the common issues?

Why calibrate this product?

Validate measurement accuracies conform to published specifications.

Factory standards to ensure accuracy

Factory standards to ensure accuracy

VIAVI Calibrates to TL9000 factory standards to ensure your instrument is certified to measure accurately, as it did when it came off the factory line.  Instruments that are out of calibration will produce unreliable measurements and can create false passing or false failing test results that often cause your team repeat work.  We maintain, polish and clean all fiber connectors, fix pigtail connections that are internal to the product to ensure all ports stay in good working order and upgrade software / firmware to the latest approved release to enable enhancements. VIAVI Care Plans are the most cost-effective way to plan for calibration with a low, discounted price at the time of instrument purchase, however fixed rate calibration can be purchased at a later date on a separate purchase order.

  • Ensure accurate measurements that meet calibration and service level agreements, ISO and TL standards for network test procedures.
  • Ensure all test transmission signals work properly to avoid issues such as not reaching full line rate testing rate required to validate service bandwidth, speed and quality of service (QoS).
  • Maintain ports and connectors to keep test transmissions working properly and to extend the life of the instrument. For example, if optical connectors and, lasers are bad or electrical/RF interface ports are loose after years of connection cycles, OTDR, TDR, and Radio Frequency measurements will not work properly.
  • When doing construction, installation and activation work that must be certified, all network components typically must be tested with a certified, calibrated instrument to preserve warranty from manufacturer, such as fiber optic cable manufactures. 
  • Accurate RF frequencies and optical wavelengths are critical to meet measurement specifications.  If using these to validate network elements, power levels, transmission rates, out of specification tools will prevent validation of network elements and signals.

How will my measurements be affected if the product is out of calibration?

Full mfg warranty (20-30 years) from cable suppliers (e.g. Corning, Commscope, Belden, ...) will only be granted if the installation is certified with a calibrated instrument.

What are the most common implications of these issues to the business?

What are the most common implications of these issues to the business?

  • Uncalibrated tools produce unreliable measurement results that can't be certified to specifications and may violate service level agreements or ISO/TL9000 standards with your customers and their network equipment vendors.
  • QoS certification may be inaccurate and generate a repeat test need. Contractors are often not compensated or could be delisted as an approved service supplier due to incorrect results.
  • Full manufacturer  warranty (20-30 years) from cable suppliers (e.g. Corning, CommScope, Belden, ect.) will only be granted if the installation is certified with a calibrated instrument, thus the network owner is motivated to comply with correct installation certification procedures to retain and enforce the warranty on expensive cabling and optical network elements, etc.

Common Business impacts include:

  • Lost revenue, customer complaints and increased costs: 
  • Most network operators track and audit repeat work done by sub-contractors and often there is a billing dispute in these cases.  Contractors with high rates of inaccurate test results are usually hired for less or not at all when not meeting SLA agreements or quality metrics.   
  • For Network Operators, repeat service quality issues with customers often causes added cost, customer dissatisfaction and loss of business.  

Example:

Let's look at OTN/SONET/SDH/E1/T1 and various FTTX, DOCIS and xDSL measurements.  It is critical to reach full line rate (1G, 10G, 40G, 100G) to test service performance and service error rates.  If the uncalibrated tester can not reach full line rate during testing, a customer may be left with suboptimal performance that will quickly create complaints or alternatively, the technician could end up chasing phantom network problems that do not exist.


Product Training Options

Self-Paced Online Training and Certification

Learn to use the functionality and features of VIAVI Solutions' products online, 24 hours a day, 7 days a week followed by a certification test upon completion of all modules.

 Self-Paced Online Training and Certification

Virtual Classroom and Certification

Instructor led Coursework: Learn from an expert Instructor from the convenience of your desk. Build your skill sets using VIAVI Solutions products to test various technologies with test and certification upon completion.

On-Site Classroom and Live Lab Workshops with Certifications

On-Site Classroom and Live Lab Workshops with Certifications

Instructor led Coursework: Build expertise using your VIAVI products in live lab exercises with test and certification upon completion. Utilize optional workshop days for field test on your network with your instructor.

Mentorship Consulting & System Admin Training

Instruments: Mentorship Test Procedure Consultation: Application Engineer Days. One of our test experts will come to your site and conduct testing with your team to troubleshoot stubborn problems or write up test procedures.

Explore More


How to Get Started

Interested in a product demonstration? Contact us for more info, receive a price quote, or find out how to buy.