Problem: 
Why do some of the OTDR section results have no slope values and others do on my Viavi OTDR?
Solution: 
When the section is very short (2Kms or less typically) and very linear then the intrinsic error starts to be come high when compared to the very small db/km loss result making it difficult to ensure an accurate result. Is this scenario the test will not report a db/km value. Other factors can also contribute such as insufficient data points for that section. In these cases, the customer can perform a manual slope measurement for that section.