When testing multiple streams to more than one destination, do the far-end test sets also have to be in a multiple-streams application?

Tuesday, December 31, 2019
Submitted by ryan.grace on July 8, 2021 - 10:32pm
Problem: 
When testing multiple streams to more than one destination, do the far-end test sets also have to be in a multiple-streams application?
Solution: 
If the far end test device is in loopback mode then they do not have to be in a multiple streams application. If they will be running head or head with the multiple streams testset then yes they also have to be in mulitple streams with the correct stream id configured.