VIAVI TestCenter: 400G Appliances - Double-click Break Link causes link to stay down
Knowledge Base - FAQ
Starting in 5.11 release, when you hit "Break link" once the "Break Link" button stays "clickable" for 2 seconds before turned grayed out, if by an error you click it again - Like a double click (I did it by error) then, when doing a Restore Link, the link took too long to comes up again. And sometimes the link LED remains RED and link doesn't come up until you bring the ports offline and online
Same issue seen in all speeds on 400G cards/appliances (DX3-QSFP-DD-8-750A)