VIAVI TestCenter: Has the VIAVI TestCenter chassis been through any conformance test with regard to the earthquake resistance? Please provide the measured the G-force (G) for both the horizontal and vertical directions at which the normal operation is confirmed.
None of the VIAVI TestCenter products are NEBS compliant. • SPT-2U and 9U were exposed to 6 axis 35G peak input. • SPT-3U and SPT-11U were exposed to 6 axis 45G peak input. The environmental stress testing gives a good indication that VIAVI TestCenter equipment will survive and operate when exposed to an earthquake. Attached is a picture referencing the vibration axis test.