VIAVI TestCenter: PX3-400G-T2 modules keep flapping between in sync and out of sync
Knowledge Base - FAQ
• This particular test involves 3 modules
• PX3-400G-T2
• PX3-100G-T12
• MX3-100G-T2
• Only the PX3-400G-T2 module was flapping in sync and out of sync
• This continues to occur even after the modules are reboot
• The ui.log shows the following:
Module 7
19/07/28 15:10:15.156 INFO 6 - user.equipment - Rebooting test module /7...
19/07/28 15:13:21.617 INFO 8 - user.equipment - Completed rebooting test module /7.
19/07/28 15:13:21.617 INFO 8 - user.chassis - Completed rebooting test module /7.
19/07/28 15:19:32.389 INFO 9 - user.equipment - test module 7 port group 1 is in sync.
19/07/28 15:19:32.389 INFO 9 - user.equipment - test module 7 port group 9 is in sync.
19/07/28 15:19:46.654 ERROR 9 - user.equipment - test module 7 port group 1 is out of sync.
19/07/28 15:19:46.654 ERROR 9 - user.equipment - test module 7 port group 9 is out of sync.
19/07/28 15:20:01.606 INFO 8 - user.equipment - test module 7 port group 1 is in sync.
19/07/28 15:20:01.606 INFO 8 - user.equipment - test module 7 port group 9 is in sync.
19/07/28 15:20:01.606 ERROR 8 - user.equipment - test module 7 port group 1 is out of sync.
19/07/28 15:20:01.606 ERROR 8 - user.equipment - test module 7 port group 9 is out of sync.
Module 8
19/07/28 15:13:42.877 INFO 8 - user.equipment - Rebooting test module /8...
19/07/28 15:17:30.151 INFO 7 - user.equipment - Completed rebooting test module /8.
19/07/28 15:17:30.151 INFO 7 - user.chassis - Completed rebooting test module /8.
19/07/28 15:19:32.389 INFO 9 - user.equipment - test module 8 port group 9 is in sync.
19/07/28 15:19:32.389 ERROR 9 - user.equipment - test module 8 port group 9 is out of sync.
19/07/28 15:19:32.389 INFO 9 - user.equipment - test module 8 port group 1 is in sync.
19/07/28 15:19:32.389 ERROR 9 - user.equipment - test module 8 port group 1 is out of sync.
19/07/28 15:19:46.654 INFO 9 - user.equipment - test module 8 port group 9 is in sync.
19/07/28 15:19:46.654 ERROR 9 - user.equipment - test module 8 port group 9 is out of sync.
19/07/28 15:20:01.606 INFO 8 - user.equipment - test module 8 port group 1 is in sync.
19/07/28 15:20:01.606 ERROR 8 - user.equipment - test module 8 port group 1 is out of sync.
• The port group FW/IL log, logfile_tsync.log, from one of the affected modules shows the following:
07-28-19 15:20:16,371 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:20:30,372 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = E6000000000000
07-28-19 15:20:44,373 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:20:58,374 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:21:12,375 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:21:26,376 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:21:40,377 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
07-28-19 15:21:54,378 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = E6000000000000
07-28-19 15:22:08,379 [140149211502400] ERROR frmwk.il.0.tsync > - portGroup off-sync; portGroup.at(1), timeDrift = 48000000000000
N/A