VIAVI TestCenter: STC 5.28 - "Verify Result Value" not working in STC Command Sequencer
Knowledge Base - FAQ
Customer has a Wifi configuration and is trying to use "Verify Result Value" in command sequencer to verify the traffic on Rx port but seems to be not working.
They've also tried in B2B test and used this option for L1 Rx Rate, Rx Rate, Frame Per Sec, etc. for >= value or between but all of these are not working.
This also have seen this issue in a back to back config:
-500 Mbps load with Pass condition RX L1 rate >=1000 Mbps – Condition passed incorrectly, should be- Failed
-500000000 bps with pass condition Rx L1 Rate >= 600000000 – Condition failed correctly.
-900000000 bps with pass condition Rx L1 Rate >= 800000000 – Condition passed correctly.
-200 Mbps load with Pass condition RX L1 rate >=600 Mbps – Condition passed incorrectly, should be -Failed