VIAVI TestCenter: Stream Results Histogram Column headings not matching what I configured under Traffic Analyzer --> Histograms?

Knowledge Base - FAQ

VIAVI TestCenter: Stream Results Histogram Column headings not matching what I configured under Traffic Analyzer --> Histograms?
Here are the Analyzer --> Histogram configurations for ports 10/5 and 10/6.  Note that port 10/5 has the first 7 bucket sizes set at 10 and port 10/6 buckets are not configured the same way. Now in the Detailed Stream Results --> Histograms view, we see generic labels (this was taken from STC 4.03 GA).  This is because the "Select Rx Ports" is set at "All Ports" and since both ports' Analyzer --> Histogram buckets aren't setup exactly the same the labels will be generic. If however we change "Select Rx Ports" to "Port //10/5" we see that the column headers reflect the way they were configured. So, unless all the ports have the same Histogram bucket configuration or a specific Rx port is selected, generic labels will be used rather than the configured bucket sizes. This includes the Stream Block Results. Also some configuration may include modules that do not support histograms. In this case you need to go to All Analyzers and set the Histogram mode all the same. See snap shot below. Note: You may also need to disable High Speed Results Analysis (HSRA) on the stream block.