VIAVI TestCenter: v4.81.2726, when stream only generation is enabled on stream block bound between a wi-fi client with a statically defined IP and an ethernet host, both with device count > 2, an IL error is thrown
Knowledge Base - FAQ
• The user configures a bound stream block between a device block on a Wi-Fi port and Ethernet port.
• The device count > 1 on both device blocks
• When the configuration is applied, the following errors are thrown
18/02/19 19:37:55.661 ERROR 18848 - fmwk.bll.core.equip - Received error response: seq 58, msgr 10.108.6.14 test module 1 port group 7, req Generator_3.SetStreamBlock, code -10001, faultMsg Stream block (downstream): Invalid input parameters: The number of hardware modifier configured was exceeded. Might use stream in modifier instead.
18/02/19 19:37:55.661 ERROR 18848 - fmwk.bll.core.rpc - Rcvd error response: seq58 msgr port //10.108.6.14/1/7 req Generator_3.SetStreamBlock code -10001 faultMsg Stream block (downstream): Invalid input parameters: The number of hardware modifier configured was exceeded. Might use stream in modifier instead.
18/02/19 19:37:55.661 ERROR 18848 - user.l2l3.streamblock - Error encountered while sending message to configure stream block(s). Stream block (downstream): Invalid input parameters: The number of hardware modifier configured was exceeded. Might use stream in modifier instead.
18/02/19 19:37:55.712 ERROR 2992 - fmwk.bll.core.equip - Received error response: seq 61, msgr 10.108.6.14 test module 1 port group 7, req Generator_3.StreamBlockLoadProfileBinding, code -10001, faultMsg Invalid input parameters: Cannot find stream block id 3358 in database.
18/02/19 19:37:55.713 ERROR 2992 - fmwk.bll.core.rpc - Rcvd error response: seq61 msgr port //10.108.6.14/1/7 req Generator_3.StreamBlockLoadProfileBinding code -10001 faultMsg Invalid input parameters: Cannot find stream block id 3358 in database.
18/02/19 19:37:55.713 ERROR 2992 - user.l2l3.streamblock - Error encountered while sending message to bind load profile(s) to stream block(s). Invalid input parameters: Cannot find stream block id 3358 in database.
• Using the same configuration file, and relocating the ports to a
SPT-C1 2 x 802.11ac Wave-1, 2 x 802.11n Wave-1, and 4 x 1G Copper
there are no apply time errors.
N/A