VIAVI TestCenter: Why does toggling AN on then off on a MX3-100GQ-T2 port, in 40G mode, in some cases allow the link to come up and in others, clears Rx errors?
Knowledge Base - FAQ
• A configuration file is loaded and applied
• 63 ports, IPv4, full mesh test
• There are two issues:
• Some ports do not link up
• Performing shut/no shut on the DUT side does nothing
• Other ports where link is up, test traffic is received with FCS, IPv4 checksum, and UDP checksum errors.
• On STC side the following actions result in the above issues being resolved:
• reboot the STC port
• changing the port's autonegotiation (AN) settings and restoring them
• In GUI, on the port that is down go to the Port level -> General tab
• change the setting from Disable AN/Disable FEC -> Enable AN + apply
then
from Enable AN -> Disable AN/Disable FEC + apply
• Reseating the DACs was not tried but it might work
N/A