What is the definition of the ONT 40GigE/100GigE PCS 64B/66B errored block counter?

Tuesday, December 15, 2020
Submitted by ryan.grace on October 23, 2021 - 8:46am
Question: 
What is the definition of the ONT 40GigE/100GigE PCS 64B/66B errored block counter?
Answer: 
The function responsible for the ONT 40GigE/100GigE PCS 64B/66B errored block counter is as defined by IEEE 802.3ba and specifically the value “E” from the R_TYPE variable description in clause 82.2.18.2.3. R_TYPE(rx_coded) This function classifies the current rx_coded vector as belonging to one of the following five types, depending on its contents. The classification results are returned via the r_block_type variable. Values: C; The vector contains a sync header of 10 and one of the following: a) A block type field of 0x1E and eight valid control characters other than /E/; b) A block type field of 0x4B. S; The vector contains a sync header of 10 and the following: a) A block type field of 0x78. T; The vector contains a sync header of 10, a block type field of 0x87, 0x99, 0xAA, 0xB4, 0xCC, 0xD2, 0xE1 or 0xFF and all control characters are valid. D; The vector contains a sync header of 01. E; The vector does not meet the criteria for any other value.

Support at Every Step

We provide support, services, comprehensive training and the resources you need. It’s all part of what we do to maximize the value of your VIAVI investment.

Value add services that compliment your VIAVI system solution and instrument portfolio to provide a total cost of ownership

Customer Service that provides Return Material Authorization (RMA) for repair and calibration

Technical education solutions, product training, and blended learning for technicians who are using new products or working with existing tools

Technical Assistance Center to assist you in using/configuring products or address issues regarding product performance