VIAVI TestCenter : Getting error "Currently configured stream count (XXXXX) for high speed result analysis on (Port XX) exceeds maximum allowed stream count (4095) per port instance."
Knowledge Base - Solution
Getting below validation error,
Currently configured stream count (65002) for high speed result analysis on (Port //5/19) exceeds maximum allowed stream count (4095) per port instance.
The current stream block configuration for port (Port //5/19) will expand to 65002 transmit streams, which is greater than the maximum port capacity of 16384 transmit streams.
Stream block (4/1_4/5/3_65000_host-2): The number of transmit streams after expansion (65000) will be greater than the port capacity of 16384 streams.
DX-10G-S32 module supports 4095 send & receive streams.