How can I set up different throughput bandwidth amounts, for the different frame sizes, when configuring the RFC 2544 on my MTS/TBERD 5800?
Answer: 
Rev 25.4 added the ability to set individual throughput amounts per frame size when configuring the RFC on the MTS/TBERD 5800. To access this feature go to the Advanced Throughput Settings and place a check mark in the Configure Max Bandwidth per Frame Size box. This will add an edit box for each selected frame size for the user to enter a max bandwidth value. 