Question: 
How is the Configured load calculated when I check the Throughput (RFC 2544) box on the Select Y.1564 Tests setup screen?
Answer: 
When you enable the Optional Measurement for Throughout RFC 2544, within Samcomplete, the unit will add up the CIR of streams 2 thru X (with X being the final stream) and then subtract that amount from the amount specified in the RFC Throughput box. That remaining amount will be assigned to Steam 1 as its load. 